Certificate of Analysis
BPC-157
Pentadecapeptide · 15 aa, gastric origin
Reading a certificate
What each test checks, how to read its result, and where a certificate stops.
A certificate of analysis (COA) is a lab report tied to a single lot. It lists each test performed, the method behind it, and the result measured on a sample taken from that lot. It speaks to one batch, not to a compound in general. A result for one lot tells you nothing about another, so each lot here has its own report, labelled with the lot number and the laboratory’s accession number.
It is an HPLC-UV area-percent figure from reversed-phase HPLC, run to USP <621>. The column splits the sample into its components, and a detector records how strongly each one absorbs ultraviolet light. Purity is the target peptide’s portion of that total signal. So a 99.6% result means 99.6% of the detected material was the target peptide. What remains is usually shortened sequences and leftovers from synthesis. Vitrapep releases lots at 99% or above, and each figure comes from that lot, not from a stand-in sample.
With liquid chromatography–mass spectrometry (LC-MS), run to USP <736>. A peptide’s formula fixes a single exact monoisotopic mass. The instrument weighs the molecule actually present in the vial and compares it with that expected value, within 5 parts per million. A wrong label, a shortened chain or a swapped analogue will not pass, since its mass no longer fits the stated sequence. The two tests do separate jobs. Identity confirms the molecule is the right one, and purity says what share of the sample it makes up.
Endotoxins sit in the outer membrane of Gram-negative bacteria, and they outlast the steps that kill the bacteria. So a material can hold them even when nothing in it is alive. The lab uses the Limulus amebocyte lysate (LAL) assay under USP <85>, in duplicate. The certificate gives the assay’s outcome, not a concentration, so treat it as a pass against the named method. It is on the report because endotoxin can skew sensitive in-vitro experiments. Cells may react to it, and that reaction can be misread as an effect of the compound under study.
Freedom Diagnostics runs the LAL endotoxin test described above. The production lab tests for lead, cadmium, mercury and arsenic (the heavy-metal panel), plus leftover solvents and moisture. It also reports impurities, pH and solubility. Taken together, these cover what else sits in the vial alongside the peptide. A PCR microbial screen is done on the Bacteriostatic Water only, not on peptide lots.
Net content is the mass the lab weighed in the vial. The label shows the nominal amount. If a 10 mg vial reports 10.17 mg, it holds a little more than the label says. Publishing the measured figure lets you check that the vial contains at least what you paid for, and lets you record the true amount instead of trusting the printed one.
Each lot goes through two rounds of testing. First, the manufacturing facility tests the batch and releases it, and we keep that report on file. When the lot reaches us, Freedom Diagnostics tests it again. That lab is an independent laboratory with no role in making or selling the material. Stock stays unsellable until both reports are on file, and a lot whose two results conflict is never sold. The second test exists so the seller is never the only one vouching for what is in the vial.
It covers the measurements printed on it and nothing more. It is no evidence of safety, effectiveness or approval for any purpose, and none of its results should be taken that way. The products are lyophilized powders in sealed vials coded by lot. They are not sterile-filled, so we make no sterility claim, and the endotoxin result above is what we report in its place. The certificate also reflects the lot at the moment the lab received it, so it cannot speak to storage or handling after that. Everything we sell is for in-vitro laboratory research. Not for human or veterinary use.
Compare the lot number on the vial with the lot number on the report. Every report also shows the accession number the lab assigned to the sample it tested, which links the result to one submission instead of a file that could be reused. Use the search above with a lot number or a compound name to open the record for your vial.